{"product_id":"attenuator-volume-control-5-zone-evac-100w-100v-line","title":"REDBACK Attenuator Volume Control 5 Zone Evac - 100V Line","description":"\u003ch2\u003eREDBACK Attenuator Volume Control 5 Zone Evac - 100V Line\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe \u003cstrong\u003eRedback 5 Zone Attenuator Volume Control Evac\u003c\/strong\u003e is a practical rackmount solution for managing speaker volume across multiple zones in a \u003cstrong\u003e100V line commercial PA system\u003c\/strong\u003e. Available from \u003cstrong\u003eConcert AV Melbourne\u003c\/strong\u003e, this unit is designed for installed audio environments where reliable zone control and emergency override functionality are essential.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eBuilt into a \u003cstrong\u003estandard 2RU 19-inch rackmount panel\u003c\/strong\u003e, this controller can be configured as \u003cstrong\u003efive single inputs to five outputs\u003c\/strong\u003e or as \u003cstrong\u003eone input to five outputs\u003c\/strong\u003e, giving installers flexible options depending on the system design. Each zone supports a \u003cstrong\u003e100W load capacity\u003c\/strong\u003e, with a \u003cstrong\u003etotal panel capacity of 500W\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFlexible 5 Zone Volume Control\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThis unit provides \u003cstrong\u003efive zone outputs\u003c\/strong\u003e, with each zone offering \u003cstrong\u003e10 volume positions plus off\u003c\/strong\u003e. That makes it a strong choice for commercial spaces where individual area control is important, including schools, offices, warehouses, hospitality venues and public buildings.\u003c\/p\u003e\n\u003ch3\u003eDesigned for 100V Line PA Systems\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe Redback attenuator is designed specifically for \u003cstrong\u003e100V line commercial PA systems\u003c\/strong\u003e. Rear-panel \u003cstrong\u003eheavy duty screw terminals\u003c\/strong\u003e make installation straightforward, while the included \u003cstrong\u003eengraving strip\u003c\/strong\u003e helps clearly label zones for easier system identification and operation.\u003c\/p\u003e\n\u003ch3\u003e24V DC Override for Evac Systems\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eA key feature of this model is the \u003cstrong\u003e24V DC override relay\u003c\/strong\u003e, which allows the volume controller settings to be bypassed when required. This makes it suitable for evacuation and emergency announcement systems where paging or alert signals need to take priority.\u003c\/p\u003e\n\u003ch3\u003eRackmount Installation Made Easy\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eHoused in a \u003cstrong\u003e2 unit (88mm) 19-inch rack panel\u003c\/strong\u003e, this attenuator is easy to integrate into professional PA racks and control systems. It is a practical option for installers who need a neat, organised and dependable multi-zone volume control solution.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e5 zone 100V line attenuator\u003c\/li\u003e\n\u003cli\u003eSuitable for commercial PA systems only\u003c\/li\u003e\n\u003cli\u003eConfigurable as \u003cstrong\u003efive single inputs to five outputs\u003c\/strong\u003e or \u003cstrong\u003eone input to five outputs\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e100W per zone\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e500W total load capacity\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 volume positions plus off\u003c\/strong\u003e on each zone\u003c\/li\u003e\n\u003cli\u003eStandard \u003cstrong\u003e2RU 19-inch rackmount\u003c\/strong\u003e design\u003c\/li\u003e\n\u003cli\u003eHeavy duty rear \u003cstrong\u003escrew terminal connections\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003eengraving strip\u003c\/strong\u003e for zone labels\u003c\/li\u003e\n\u003cli\u003eSupplied with \u003cstrong\u003edouble-sided tape\u003c\/strong\u003e for strip fitting\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003e24V DC override relay\u003c\/strong\u003e for bypassing controller settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWho Is It For?\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe Redback 5 Zone Attenuator is ideal for:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eCommercial PA installations\u003c\/li\u003e\n\u003cli\u003eEvacuation and paging systems\u003c\/li\u003e\n\u003cli\u003eSchools and public buildings\u003c\/li\u003e\n\u003cli\u003eWarehouses and industrial sites\u003c\/li\u003e\n\u003cli\u003eHospitality and retail venues\u003c\/li\u003e\n\u003cli\u003eInstallers building multi-zone 100V line systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOur Take\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eIf you need reliable \u003cstrong\u003emulti-zone volume control\u003c\/strong\u003e in a \u003cstrong\u003e100V line installation\u003c\/strong\u003e, this Redback unit is a very practical choice. The combination of \u003cstrong\u003efive zone control\u003c\/strong\u003e, \u003cstrong\u003erackmount design\u003c\/strong\u003e, \u003cstrong\u003eclear labelling options\u003c\/strong\u003e and \u003cstrong\u003e24V override capability\u003c\/strong\u003e makes it well suited to commercial and evacuation-focused PA systems.\u003c\/p\u003e\n\u003cp\u003eAvailable now from \u003cstrong\u003eConcert AV Melbourne\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"REDBACK","offers":[{"title":"Default Title","offer_id":41162602086472,"sku":"A2365","price":575.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0567\/9936\/3144\/files\/ca29e838-f363-4310-a3fb-f582f2af5319.jpg?v=1781749812","url":"https:\/\/concertav.com.au\/products\/attenuator-volume-control-5-zone-evac-100w-100v-line","provider":"Concert Audio Visual Pty Ltd","version":"1.0","type":"link"}